850VA UPS with AVR, advanced

UPS-PC-850AP

850VA UPS with AVR, advanced

UPS-PC-850AP
  • ULTIMATE DEFENCE
  • Provides backup power - prevents data loss
  • Protects your sensitive and valuable equipment
  • Compact and reliable - ideal for home and small office use

Uninterruptable 850 VA power supply for PC’s
Automatic output voltage regulation (AVR)
USB interface
LED status indication
Short circuit protection
Surge, spike and lightning protection
Audible and visual alarms
Overcharge and overdischarge protection
Including practical UPS Management software

UPS type: line interactive
Input: AC 162 - 295 V, 50 Hz / 60 Hz ± 10 %
Output: AC 188 - 254 V, 50 Hz / 60 Hz ± 0.5 % (on battery)
Waveform: sine wave (AC mains), simulated sine wave (battery)
Temperature compensation:  -20mV/1 °C (per cell)
Switching time: no more than 10 ms
Backup time: 8...20 mins (depends on the load)
Battery: sealed lead-acid 12V/7Ah x 1 pc
Charge time: up to 12 hours
Sockets: 1x C14 input, 2x C13 outputs; USB-BF connector
Operating conditions: 0 °C~40 °C, at humidity 20~90 %RH non condensing
Power: 850 VA (520 W)
Dimensions: 340 x 95 x 165 mm
Product weight: 7 kg
"Cold-start" function

Software is compatible with Windows 7, Windows 2008 server, Windows 8/10/11
In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work.


UPS-PC-850AP
Q: UPS switches off automatically after a very short time, but the battery indicator still shows (almost) full battery.
A: Every UPS has a certain maximum power output (W), but also a minimum required load. In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work. Otherwise it will shut itself down automatically as a safety measure to preserve the batteries. Also when the connected load is higher than the maximum capacity of the UPS, the device will shut down.
Q: UPS switches off automatically after a very short time, but the battery indicator still shows (almost) full battery.
A: Every UPS has a certain maximum power output (W), but also a minimum required load. In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work. Otherwise it will shut itself down automatically as a safety measure to preserve the batteries. Also when the connected load is higher than the maximum capacity of the UPS, the device will shut down.
Package contents
UPS
Power cord
USB cable
Software CD
Spare fuse
Packing details
Q'ty in crtn, pcs3
Crtn volume, CUM0.053475
Crtn weight, kgs21
Individual package size LxWxH:375x145x230 mm
Carton size LxWxH:460x375x310 mm
Country of originCN
Barcode8716309057066
Customs code8504408590
Packagingcolor box

Trade Mark

Product information sheet

You might also need

CCP-USB2-AMBM-6G

USB 2.0 A-plug B-plug 6ft cable, grey color

PC-186-VDE-10M

Power cord (C13), VDE approved, 10 m

BAT-12V7AH

Battery 12V 7AH

PC-189-VDE-3M

Power cord (C13 to C14), VDE approved, 3 m

BAT-12V7.5AH

Battery 12V 7.5AH